1. Home
  2. Projects
  3. Networks and conveyance lines
  4. Tulkarem Wastewater Collection System Improvements – Irtah Pump Station and Force Main

Tulkarem Wastewater Collection System Improvements – Irtah Pump Station and Force Main

Tulkarem Wastewater Collection System Improvements – Irtah Pump Station and Force Main

Key facts

Pipe length
About 6,800 m gravity sewers; about 2,700 m force main
Structure
New Irtah sewage pump station
Equipment
Screens, pumps, electrical and control systems, flow meter
Scope
Pump station, gravity sewers and force main
Locations
Tulkarem, West Bank

MACC built a new sewage pump station at Irtah, new gravity sewers and a force main to the oxidation ponds for Tulkarem Municipality under the USAID-funded Tulkarem Wastewater Collection System Improvements Project. The project replaces the out-of-service Irtah pump station and extends collection to unserved parts of the city, so that wastewater no longer flows untreated into open wadis.

Scope of work

  • New Irtah pump station with screens, pumps, electrical and control systems
  • About 6,800 m of new gravity sewers in unserved parts of Tulkarem
  • About 2,700 m of force main from the Irtah pump station to the oxidation ponds
  • Screen and flow meter at the oxidation ponds